23 Oct 2008 News for NTIA/ITS HF Propagation Models (WINDOWS version) 23 Oct 2008 1. Someone pointed out that while using VOACAP or ICEPAC Point-to-Point that Method=23 had a problem. Method 23 (in the original IONCAP) was used to specify different different output variables in the RUN/CIRCUIT option. But with the development of Method 30 (Short/Long path smoothing), certain problems occurred. Thus, Method 23 allowed you to specify which calculation model to use: 20 = default (<10,000km=short >10,000km=long) 21 = forced long path model 22 = forced short path model 30 = <7,000km=short >10,000km=long smooth in between Now, if you had selected Method 23 and then 30 for the model, RUN/CIRCUIT was fine. But RUN/GRAPH, RUN/DISTANCE, and RUN/TIME used 20 for the calculations. This has now been fixed to use the calculation model selected. This was never a problem with REC533 because its short/long path calculation model is fixed. 2. Let me know if there are any problems with Windows Vista systems. 3. This is a minor change from the vewsion 081022 that had an install problem.